Gateway and Gateway 4 Manual v1.5

Navigation: Using the HTML5 Toolbox Web-GUI

Digest Upgrade Hold Off

Scroll Prev Top Next More

The Digest Upgrade Hold Off setting is accessed via the System tab in the Options panel in the Toolbox web-GUI. It is also accessible from the codec front panel via Settings > Miscellaneous.

 

Options_panel-Digest_upgrade_holdoff

 

The Digest Upgrade Hold Off value influences the Connection panel and Cloud Codec Controller (CCC) connection LEDs by maintaining the lowest LQ value that a connection, stream and program has been in for the last X seconds. The default setting is 0 and in nearly every situation this is the recommended configuration. DO NOT change this setting if you are unsure of its effect on the display in the Connection panel or CCC. LED display settings are as follows:

 

Gray: Not In use

Green: Connected and stable (LQ greater than 70)

Yellow: Connected but connection quality is not stable (LQ 50 to 70)

Red: Connection establishing or problem with connection (LQ less than 50). LED flashes when establishing connection.

 

Note: ISDN connections do not display the yellow LED state.

 

To adjust the setting in the System tab in the Options panel:

 

1.Click Edit.

2.Adjust the Digest upgrade hold off period in seconds.

3.Click Save.